Professional, High Efficiency and Intelligent WVTR Test System
Technical Specifications
Specifications | Film Test | Package Test (Optional) |
---|
Test Range | 0.01 ~ 40 g/m2·24h (Standard) 0.1 ~ 1000 g/m2·24h (Optional) | 0.0001 ~ 0.2 g/pkg·d |
---|
Specimen Size | 108 mm x 108 mm | Temperature control for one package test: < Ф180 mm, Height < 380 mm |
---|
Temperature control for 3 package test: < Ф100 mm, Height < 380 mm |
No size limitation for tests without temperature control device |
Number of Specimen | 3 with independent test results |
---|
Specimen Thickness | ≤3 mm | / |
---|
Test Area | 50 cm2 | / |
---|
Temperature Range | 15°C ~ 55°C (standard) |
---|
Temperature Accuracy | ±0.1°C (standard) |
---|
Humidity Range | 0%RH, 35%RH ~ 90%RH, 100%RH |
---|
Humidity Accuracy | ±1%RH |
---|
Carrier Gas | 99.999% high-purified nitrogen (outside of supply scope) |
---|
Flow of Carrier Gas | 0 ~ 200 mL/min |
---|
Pressure of Carrier Gas | 0.28 MPa/40.6 psi |
---|
Port Size | 1/8 inch copper tubing |
---|
Instrument Dimension | 690 mm (L) x 350 mm (W) x 360 mm (H) |
---|
Power Supply | AC (85 ~ 264)V (47 ~ 63)Hz |
---|
Net Weight | 70 kg |
---|
Principle
Infrared method is used by W3/230 Water Vapor Transmission Rate Test System: The test specimen is mounted in the diffusion cell, which is subsequently divided into a dry chamber and a controlled-humidity chamber. The dry side of the specimen is swept by a flow of dry nitrogen, and the water vapor permeating through the specimen from the controlled-humidity chamber is carried by dry nitrogen to the infrared sensor where proportion electrical signals will be generated. The water vapor transmission rate is obtained by analyzing and calculating the electrical signals. For package samples, dry nitrogen flows inside the package, and moisturized nitrogen flows outside.
Standards
This test instrument conforms to the following standards:
ISO 15106-2, ASTM F1249, GB/T 26253-2010, TAPPI T557, JIS K7129
This instrument is applicable to the determination of water vapor transmission rate of:
Basic Applications | Films Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others |
---|
Sheeting Including engineering plastics, rubber, building materials and other sheet materials, e.g. PP, PVC and PVDC |
Paper and Paper Board Including paper and paper board, e.g. aluminized paper for cigarette packages and paper, plastic and aluminum composite materials |
Packages Including plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. Coke bottles, peanut oil packages, Tetra Pak materials, vacuum bags, metal three-piece cans, soft tube packages for cosmetic and toothpaste, and jelly cups |
Extended Applications | Package Caps Test seal performance of different package caps |
---|
LCD Monitor Films WVTR test of LCD monitor films |
Solar Back-Sheets WVTR test of solar back sheets |
Plastic Packages for Drugs and Health Care Products Test water vapor transmission rate of plastic bottles for drug and health care products, e.g. eye drop bottles, infusion bags and health care product packages |
Plastic Pipes Including various sorts of pipes, e.g. PPR |
Blister Packs Blister packs for pharmaceutical products |
Aseptic Wound Protection Films and Medical Plasters Including aseptic wound protection films and medical plasters |
Fuel Tanks of Cars Plastic fuel tanks are widely used in cars for its light weight, buffering vibration and easy molding characters. But its fuel permeability is the most essential factor. This instrument can be used to test permeability of plastic fuel tanks |
Battery Plastic Shells Battery electrolyte is protected by the plastic shell from outside environment. Battery service life is directly depended on its water vapor permeability. This instrument can be used to test water vapor transmission rate of battery plastic shell |
Paper Cups and Bowls Test water vapor transmission rate of the whole packages for instant noodles and disposable paper cups |
Professional
W3/230 Water Vapor Transmission Rate Test System is designed for the determination of water vapor transmission rate of film and package specimens. It has three test modes and is applicable to various materials with high, medium and low water vapor permeability. It is also embedded with high precision infrared sensor, which provides a wide test range of 0.1~1000g/m2·24h and durable service life.
Wide range and high-precision of temperature and humidity control to support various combinations of non-standard test conditionsStandard, proportional, and continuous testing modes facilitate to test different materials with distinct water vapor permeabilityConvenient fast-access calibration ports for temperature and humidityReference film for fast and accurate calibrationHigh Efficiency
W3/230 system is based on the infrared sensor method and utilizes Labthink’s latest exclusive patent design of three diffusion cells integrated in one instrument for individual or multiple tests, which improves test efficiency by 3 times.
Embedded computer control system provides safer and more reliable data management as well as test operation. Three diffusion cells are integrated in one instrument with lower space occupancy rate and higher test efficiencyThree distinct or equivalent specimens can be tested individually with independent test results at one operationThe instrument can be easily operated with a mouse, a keyboard, and a monitor, without requiring a PCThe instrument is equipped with four USB ports and dual Internet ports for convenient data transmissionIntelligent
The instrument is equipped with the latest operating software, with user-friendly operating interface and intelligent data management functions. It also supports LystemTM Lab Data Sharing System, which ensures uniform management of test results and test reports.
Intelligent designs for test result evaluation, sensor calibration reminding, tracing or managing operation record provide a safe and easy operation environmentEmbedded help document is convenient for user viewingDetailed information for each test can be saved through embedded database storage technology, and users could view historical test data in various patterns.